65765/F Vitamin C in Plasma/Serum - Automated HPLC
- 公司名稱 北京祥生興業(yè)科技有限公司
- 品牌 CHROMSYSTEMS
- 型號 65765/F
- 產(chǎn)地
- 廠商性質(zhì) 代理商
- 更新時(shí)間 2024/9/19 14:19:33
- 訪問次數(shù) 106
聯(lián)系方式:張先生13681184382 查看聯(lián)系方式
聯(lián)系我們時(shí)請說明是化工儀器網(wǎng)上看到的信息,謝謝!
溫馨提示:僅用于科研,不可用于臨床治療
- 英文名:
Vitamin C in Plasma/Serum - Automated HPLC
- 供應(yīng)商:
祥生興業(yè)
- 規(guī)格:
480 Tests
- Vitamin C
- High stability of processed samples and controls
- Enhanced column stability
- Reliable quantification with a stable internal standard
- Place 100 µl Internal Standard in a 96 well filter plate.
- Add 100 µl sample/calibrator/control.
- Vortex for 30 s at 1100 rpm (orbit: 2 mm).
- Centrifuge for 5 min at 2000 x g.
- Close the 96 well filter plate.
- Vortex for 30 s at 800 rpm (orbit: 2 mm).
- Inject 20 µl of the prepared sample into the HPLC system.
Vitamin C in Plasma/Serum - Automated HPLC
Order no.: 65765/F480 Tests
Automated sample preparation with 96 well filter plates
DESCRIPTION
Clinical relevance
Vitamin C (ascorbic acid, ascorbate) is a water-soluble vitamin that is an essential cofactor for the human body, for instance in the catabolism of tyrosine and the synthesis of catecholamines. Regular consumption of fruit and vegetables is usually sufficient to cover the body’s vitamin C needs.
In the case of vitamin C deficiency, procollagen chains are produced insufficiently and stable fibrils cannot be formed in the affected cells. Without functioning collagen, the blood vessels and tendons become fragile and the typical skin-related symptoms associated with scurvy start to develop. In addition to the collagen damages described above, further diseases caused by vitamin C deficiency include bleeding of uncertain origin, loss of teeth and overactive thyroid gland (hyperthyroidism). Vitamin C deficiency is also observed in dialysis patients, in chronic alcohol abuse and during pregnancy.
Product advantages
This Chromsystems kit allows the reliable chromatographic determination of vitamin C in one isocratic HPLC run with UV detection. An efficient protein precipitation step removes interfering components and stabilises Vitamin C simultaneously. A stable internal standard is used for reliable quantification. Due to a special stabilisation of the prepared samples, it is also possible to reliably process and measure large sample batches.
Kit content
Mobile Phase, 1000 ml
Vitamin C Plasma Calibration Standard (lyoph.), 5 x 0.5 ml
Internal Standard, 10 ml
96 Well filter plates, 5 pcs.
Collection plates, 5 pcs.
Pierceable adhesive seals for 96 well plates, 5 pcs.
CHROMATOGRAM
TECHNICAL DATA
Method of Analysis
HPLCNumber of Tests
480Parameter
Vitamin CAnalysis Time
5 minLimit of quantification
0.5 mg/l
Linearity
up to 120 mg/lIntraassay
CV <= 3 %
Interassay
CV < 6 %Information
Any isocratic HPLC system with UV detection is suitable.Specimen
Plasma/SerumPre-analytic Treatment
Specimens: Fresh lithium heparin plasma
Sample stability: 5 days at -20 °C, up to 2 hours at room temperature
Detailed information on stability and transportation can be obtained from the instruction manual.
Sample Preparation
Additional Info
For the Chromsystems HPLC analysis of vitamin C any isocratic HPLC system with UV detection is suitable.
Injection Volume
20 µlFlow rate
1.5 ml/minFlow
1.5 ml/minGradient
IsocraticColumn temperature
ambient (~25 °C)Wavelength
245 nmPlease note
The freely available information on this website, in particular on the sample preparation, are not sufficient to work with our products. Please read instructions and warning notices on products and/or instruction manuals.KIT COMPONENTS
Components available separately
Mobile Phase
Order no.: 65001
DETAILS
Mobile Phase, 10 x 1000ml
Order no.: 65002
DETAILS
Vitamin C Plasma Calibration Standard
Order no.: 65003
DETAILS
Internal Standard
Order no.: 65044
DETAILS
96 Well Filter Plates
Order no.: 65757
DETAILS
Collection Plates
Order no.: 65758
DETAILS
Pierceable adhesive seals for 96 Well Plates
Order no.: 65759
DETAILS
ACCESSORIES
PEEK prefilter housing
Order no.: 15010
DETAILS
HPLC column
Order no.: 65100
DETAILS
PEEK-encased prefilter, 5 µm
Order no.: 15009
DETAILS
Precolumn cartridge 4/10
Order no.: 18065
DETAILS
Precolumn cartridge holder 4/10
Order no.: 18001
DETAILS
CALIBRATORS
Calibrators available separately
Vitamin C Plasma Calibration Standard
Order no.: 65003
DETAILS
CONTROLS
Controls available separately
Vitamin C Plasma Controls
DETAILS