欧美……一区二区三区,欧美日韩亚洲另类视频,亚洲国产欧美日韩中字,日本一区二区三区dvd视频在线

廈門慧嘉生物科技有限公司
初級會員 | 第10年

18906011628

當前位置:首頁   >>   資料下載   >>   CSB-E04883h人β2微球蛋白(BMG)ELISA試劑盒說明書

CSB-E04883h人β2微球蛋白(BMG)ELISA試劑盒說明書

時間:2012-1-4閱讀:152
分享:
  • 提供商

    廈門慧嘉生物科技有限公司
  • 資料大小

    99.4KB
  • 資料圖片

  • 下載次數

    153次
  • 資料類型

    WORD 文檔
  • 瀏覽次數

    152次
點擊免費下載該資料

 

 Human β2-microglobulin(β2-MG) ELISA Kit
Catalog No. CSB-E04883h
(96 tests)
This immunoassay kit allows for the in vitro rapid detection of human β2-MG concentrations in serum, plasma.
Expiration date six months from the date of manufacture
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
 
廈門慧嘉生物長期經營ELISA試劑盒及Santa/Abcam抗體、Prospec細胞因子、Sigma/Amresco/Qiagen、Axygen耗材等生物試劑產品。誠信經營,價格實惠,服務周到,質量有保證。歡迎廣告老師來詢!:   :  1048735792 或登陸http://www.biohj.com/download.aspx(向客服人員索取原版說明書)
 
This assay employs the competitive inhibition enzyme immunoassay technique. An antibody specific to β2-MG has been pre-coated onto a microplate. Standards or samples are added to the appropriate microtiter plate wells with HRP-conjugated β2-MG and incubated. A competitive inhibition reaction is launched between β2-MG (Standards or samples) and HRP-conjugated β2-MG with the pre-coated antibody specific for β2-MG. The more amount of β2-MG in samples, the less antibody bound by HRP-conjugated β2-MG. Then the substrate solutions are added to the wells, respectively. And the color develops in opposite to the amount of β2-MG in the sample. The color development is stopped and the intensity of the color is measured.
DETECTION RANGE
The standard curve concentrations used for the ELISA’s were 10μg/ml, 2.5μg/ml, 0.5μg/ml, 0.1μg/ml, 0.025μg/ml.
SPECIFICITY
This assay recognizes human β2-MG. No significant cross-reactivity or interference was observed.
The minimum detectable dose of human β2-MG is typically less than 0.01 μg/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero.
MATERIALS PROVIDED

Reagent
Quantity
Assay plate
1
Standards (S1-S5)
5 x 0.5 ml
HRP-conjugate
1 x 6 ml
Wash Buffer
1 x 15 ml (20×concentrate)
Substrate A
1 x 7 ml
Substrate B
1 x 7 ml
Stop Solution
1 x 7 ml

Standard
S1
S2
S3
S4
S5
Concentration (μg/ml)
0.025
0.1
0.5
2.5
10

 
1.    Unopened test kits should be stored at 2-8?C upon receipt and the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit, provided it is stored as prescribed above. Refer to the package label for the expiration date.
2.    Opened test plate should be stored at 2-8?C in the aluminum foil bag with desiccants to minimize exposure to damp air. The kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
3.    A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
 
TECHNICAL HINTS
1. Bring all reagents and plate to room temperature for at least 30 minutes before use. Unused wells need store at 2-8and avoid sunlight.
2. Wash Buffer If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have compley dissolved. Dilute 15 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 300 ml of Wash Buffer.
3. To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
4. When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, and/or rotating the plate 180 degrees between wash steps may improve assay precision.
5. Substrate Solution should remain colorless or light blue until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless or light blue to gradations of blue.
6. Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.
 
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
 
1          Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
2          Pipettes and pipette tips.
3          Deionized or distilled water.
4          Squirt bottle, manifold dispenser, or automated microplate washer.
5          An incubator which can provide stable incubation conditions up to 37°C±0.5°C.
 
SAMPLE COLLECTION AND STORAGE
Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 x g. Remove serum and assay immediay or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 x g within 30 minutes of collection. Assay immediay or aliquot and
 
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate. All the reagents should be added directly to the liquid level in the well. The pipette should avoid contacting the inner wall of the well.
1 Set a Blank well without any solution. Add 50μl of Standard or Sample per well. Standard need test in duplicate.
2 Add 50μl of HRP-conjugate to each well (not to Blank well), Mix well and then incubate for 1 hour at 37°C.
3 Fill each well with Wash Buffer (about 200μl), stay for 10 seconds and Spinning. Repeat the process for a total of three washes. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
4 Add 50μl of Substrate A and Substrate B to each well, mix well. Incubate for 15 minutes at 37°C. Keeping the plate away from drafts and other temperature fluctuations in the dark.
wells containing the highest concentration of standards
develop obvious blue color. If color change does not appear
uniform, gently tap the plate to ensure thorough mixing. 6 Determine the optical density of each well within 10 minutes,
using a microplate reader set to 450 nm.
CALCULATION OF RESULTS
Using the professional soft "Curve Exert 1.3" to make a standard curve is recommended, which can be downloaded from our web.
Average the duplicate readings for each standard, Blank, and sample and subtract the optical density of Blank. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the β2-MG concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the
LIMITATIONS OF THE PROCEDURE
1          The kit should not be used beyond the expiration date on the kit label.
2          Do not mix or substitute reagents with those from other lots or sources.
3          Any variation in operator, pipetting technique, washing technique, incubation time or temperature, and kit age can cause variation in binding.
4          This assay is designed to eliminate interference by soluble receptors, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.

會員登錄

×

請輸入賬號

請輸入密碼

=請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復您~
撥打電話
在線留言
男人草女人的视频免费看| 看女生b免费视频| 中文字幕一区二区 在线| 国产乱子伦视频一区二区三区| 午夜理论理论亚洲激情| 日本熟妇一区二区三区四区| 伊人网在线视频观看| 92婷婷伊人久久精品一区二区| 国产精品熟女一区二区三区久久夜| 国产无码福利一区| 精品一区二区三区成人免费视频| 欧美99热这里都是精品| 亚洲福利小视频在线观看| 久久亚洲精品中文字幕一| 国产精品无码一二区免费| 97青青草免费在线观看| 有关日本黄色录像的视频| 性一交一子一伦一乱| 欧美亚洲综合一区二区三区| 国产午夜高清无码一级片| 一级毛片完整版免费播放一区| 精品无码国产一区二区三区A| 国产高清一区二区三区四区色| 瓯美在线免费视频笫一区第二区| 野外日逼视频免费看| 成年女人永久看片视频 | 黑丝美女被操哭边操边尿| 中文字幕亚洲精品女同一页| 国产亚洲一区白丝在线观看| 久久久中文字幕一区| 国产激情内射免费精品| 男生舔女生下面黄色视频| 啊啊不要你那痛死爽死了直播一区| 国产伦精品一区二区三区视频抖音| 国产女主播喷出白浆视频| 国产乱精品一区二区三区视频了| 大鸡巴狂插嫩逼视频| 韩国年轻的母亲在线观看| 色综合色狠狠天天综合色| 欧美亚洲另类天天综合网| 亚洲福利左线观看|