Thermocouple Converter | | KFD0-TT-Ex1 | | | | | | | | | | 1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges, Input: Thermocouple, Rated voltage: 12 ... 35 V DC loop powered, Output: 4-20 mA, Output, current sink, Explosion protection: Ex-Input | | | | | |
| | | Temperature Converter with Trip Values | | KFD2-GUT-Ex1.D | | | | | | | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), TC, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTwareTM or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL2 acc. to IEC 61508, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA | | | | | |
| | | Potentiometer Converter | | KFD2-PT2-Ex1 | | | | | | | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 10 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Input: Resistance, Rated voltage: 20 ... 35 V DC, Output: 0-10 V, Explosion protection: Ex-Input | | | | | |
| | | Potentiometer Converter | | KFD2-PT2-Ex1-4 | | | | | | | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 0 mA ... 20 mA, Lead resistance compensation adjustment, Accuracy 0.05 %, Input: Resistance, Rated voltage: 20 ... 35 V DC, Output: 0-20 mA, Explosion protection: Ex-Input | | | | | |
| | | Transformer isolated barrier for potentiometer | | KFD2-PT2-Ex1-6-Y112844 | | | | | | | | | | 1-channel, Input Ex ia IIC, 24 V DC nominal supply voltage, Current output 0 mA ... 24 mA, Accuracy 0.05 %, EMC acc. to NAMUR NE 21, Input: Resistance, Rated voltage: 20 ... 35 V DC, Output: 0-20 mA, Explosion protection: Ex-Input | | | | | |
| | | Universal Temperature Converter | | KFD2-UT2-Ex1 | | | | | | | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), TC, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTwareTM, Line fault (LFD) and sensor burnout detection, Up to SIL2 acc. to IEC 61508, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 4-20 mA, Explosion protection: Ex-Input | | | | | |
| | | Universal Temperature Converter | | KFD2-UT2-Ex1-1 | | | | | | | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), TC, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTwareTM, Line fault (LFD) and sensor burnout detection, Up to SIL2 acc. to IEC 61508, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 0-5 V, Explosion protection: Ex-Input | | | | | |
| | | Universal Temperature Converter | | KFD2-UT2-Ex2-1 | | | | | | | | | | 2-channel isolated barrier, 24 V DC supply (Power Rail), TC, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTwareTM, Line fault (LFD) and sensor burnout detection, Up to SIL2 acc. to IEC 61508, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 0-5 V, Explosion protection: Ex-Input | | | | | |
| | | Strain Gauge Converter | | KFD2-WAC2-Ex1.D | | | | | | | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input, Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, Relay contact output, Programmable high/low alarm, Configurable by PACTwareTM or keypad, RS 485 interface, Line fault detection (LFD), Input: DMS bridges, Rated voltage: 20 ... 35 V DC, Output: 4-20 mA | | | | | |
| | | Strain Gauge Converter | | KFD2-WAC2-Ex1.D-Y189512 | | | | | | | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input, Output 0 mA ... +- 20 mA or 0 V ... +- 10 V, Relay contact output, Programmable high/low alarm, Configurable by PACTware TM or keypad, RS 485 interface, Low response time, Line fault detection (LFD), Input: DMS bridges, Rated voltage: 20 ... 35 V DC, Output: 4-20 mA, Limit alarm relay, Display, Explosion protection: Ex-Input | | |