Nortec 2000D+渦流探傷儀具有以下功能:50 Hz~12 MHz的頻率范圍、單頻或雙頻操作、使用方便的數(shù)字式電導(dǎo)率,還可支持旋轉(zhuǎn)掃查器。因此這款設(shè)備成為多種航空航天材料無損檢測應(yīng)用的理想探傷儀。

Olympus NDT 奧林巴斯 Nortec 2000D渦流探傷儀

 

The Nortec 2000D+ offers a frequency range of 50 Hz to 12 MHz for applications ranging from detection of cracks in tubes or structures to the discovery of minute flaws in aircraft materials. Single or dual frequency operation, easy to use digital conductivity, and rotating scanner support make the flaw detector ideal for numerous aerospace NDT applications.

Customer-interchangeable displays offer excellent visibility in any lighting condition. A VGA output drives a heads up display for inspection where conditions may be cramped or a large desktop monitor or projector for classroom training.

At less than 4 lbs (1.8 Kg), the rugged Foreign Object Debris (FOD) free case will survive harsh field and production environments. An adjustable tilt bail and anti-slip bumper allow the unit to be placed on just about any surface.

The Nortec 2000D+ incorporates our unique PowerLink™ software, which provides automatic probe recognition and documentation. The instrument can be set-up by recalling the program stored in the PowerLink™ chip, providing integrity and repeatability of inspection results.

As many as 120 programs can be stored and recalled later. Date and time are recorded with each set-up and are easily identified with alphanumeric values up to 29 characters long. 20 memory locations are available to store eddy current displays..

Features

• 50 Hz - 12 MHz frequency range 
• Single Li-Ion battery 
• Lightweight, less than 4lbs. (1.8 Kg) 
• Digital conductivity in International Annealed Copper Standard (%IACS) or Mega Siemens per meter (MS/m) 
• Non-conductive coating readings in inches or millimeters 
• Multiple scanner support 
• Internal balance loads for single coil probe support 
• Customer interchangeable displays: 
- Hi-Brite Electroluminescent 
- Monochrome Liquid Crystal 
- Color Liquid Crystal 
• Dual Frequency 
• VGA Output 
• Display Freeze to hold flaw signals 
• PowerLinkTM Technology - automatic probe recognition and instrument set-up 
• Split screen presentation with color coded soft keys 
• On screen reference memory for go/no go applications 
• On board storage of 120 programs 
• Waterfall display 
• Windows-based EddyMaster™ Software

 

Nortec 2000D+ Specifications*

BASIC PERFORMANCE
FrequencyRange: 50 Hz - 12 MHz
Gain: 0 - 90 dB in 0.1 dB steps. The horizontal and vertical gains may be adjusted separay or together.
Rotation: Variable 0º - 359º
Sweep: Variable from 0.005 - 4 seconds per division
LowPassFilter: 10 - 500 Hz and wide band
HighPassFilter: Off, 2 to 500 Hz. 2 pole response
Probe Drive: 2, 6, 12 volts
Variable Persistence: Screen persistence can be varied from 0.1 - 5 seconds.
Probe Types: Absolute and differential in either bridge or reflection configuration. The instrument is fully compatible with NORTEC PowerLink™ probes.
Alarms: Can be set to trigger on positive or negative
Alarm Modes: 1-3 box gates, polar, sweep, conductivity, and coating thickness
Trace Storage: 20 traces can be stored for recall. The traces can be static or frozen. They can contain up to 60 seconds of movement. The traces are stored with the date and time of capture.
Program Storage: 120 instrument set-ups may be stored and recalled. The date and time of storage is recorded with each set-up.
Print Out: Provides a custom configurable report header containing the display screen data and probe parameters including serial number (PowerLink™ probes only)
Printers: Any serial printer

 

Inputs / Outputs
Power: 7-pin connector to charge the internal battery and operate the instrument on AC power
RS-232: DB-9P connector, bi-directional serial data via RS-232
Probe Connector: 16-pin LEMO
Analog Outputs: Horizontal and Vertical outputs of both F1 and F2. +/- 5 volts, 1 volt per division
Alarm Outputs: 9-pin analog and alarm output connector
VGA Output
General
Dimensions: 9.5" L x 5.5" H x 3.6" D (215 mm x 165 mm x 92 mm)
Weight: 3.8 lbs. (1.7 Kg) with battery
Display: Customer-interchangeable QVGA displays (320 x 240 pixels): color or monochrome LCD, Hi-Brite electroluminescent
Operating Temperature: 14° F to 122° F (-10° C to 50° C), depending on configuration
Storage Temperature: -60° F to 160° F (-51° C to 71° C), depending on configuration
Humidity: 5 to 95%
Classification: Based on Class 2 specifications from the MIL-PRF-28800F handbook
Altitude: Maximum operating and non-operating altitude - 15,000 ft. (4600 m)


Hazardous Area Operation: Safe operation as defined by Class I, Division 2, Group D, as found in the National Fire Association Code (NFPA 70), Section 500, and tested using MIL-STD-810F, Method 511.4, Procedure 1

Power 
Power Requirements: 85 to 240 volts, 50-60 Hz. External holder charges batteries outside the instrument. Charging time is typically 4 hours. 
Low Battery Protection: Display bar graph "gas gauge" indicates approximate operating time. 
Battery Operating Time: 8 hours (nominal depending on configuration)

Conductivity 
Frequency: 60 kHz or 480 kHz 
Probe Type: NORTEC Conductivity Probe 
Digital Conductivity Specification: Digital conductivity display from 0.9% to 110% IACS or 0.5 to 64 MS/m. Accuracy within +/- 0.5% IACS from 0.9% to 65% IACS and within +/- 1.0% of values over 62%. Meets or exceeds BAC 5651 specifications. 
Non-Conductive Coating Thickness: Can measure non-conductive coating thickness from 0" to 0.015" (0 to 0.38 mm). Accuracy of +/- 0.001" (0.025 mm) over 0.00 to 0.015" (0 to 0.38 mm) range

Scanners 
Scanner Compatibility: Will operate all Olympus Nortec and other commercially available scanners 
Waterfall Display: Stores up to 60 sweeps per hole and includes an on screen readout of the distance to the defect from the start of the scan (PS-5 only)

Dual frequency 
Frequency Extension: 50 Hz to 12 MHz 
Second Frequency: 50 Hz to 3 MHz, 2nd frequency is an exact division of the first frequency in ratios of: 1/2 (F1 < 6 MHz), 1/4, and even divisors to 1/32. 
Display: Frequency 1 (F1) only, Frequency 2 (F2) only, sum of F1 and F2, difference between F1 and F2, split screen with selected combinations of F1 and F2 and mixed frequencies 
High Pass Filter: Available in Frequency 1 (F1) only

Standard Inclusions 
Operating Manual 
Power Cord 
Li-Ion Battery 
Universal Barrery Charger 
Carry Case 
Protective Soft Cover 
VGA Cable 
Calibration Certificate

*All specifications are subject to change without notice.

會員登錄

X

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個,單個標(biāo)簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復(fù)您~
撥打電話
在線留言
十九禁止观看无码视频-亚洲国产激情福利专区| 欧美精品午夜一二三区-a屁视频一区二区三区四区| 亚洲精品一区网站在线观看-黄页视频免费观看网站| 中文字幕日韩不卡久久-五月天中文字幕啊av| 中文字幕亚洲中文字幕-丰满老妇伦子交尾在线播放| 日韩精品亚洲不卡一区二区-成人网在线视频精品一区二区三区| 国产精品一区二区在线免费-久久精品国产亚洲av热明星| 久久精品人妻一区二区三区极品-久久99热这里只有精品免费| 亚洲欧美精品在线一区-99热国产在线手机精品99| 中文字幕社区电影成人-欧美精美视频一区二区三区| 国产老熟女激情小视频-成人一区二区人妻不卡视频| 青青草原免费国产在线视频-精品人妻乱码一区二区三区四区| 欧美视频在线观看国产专区-亚洲91精品在线观看| 欧美视频在线观看国产专区-亚洲91精品在线观看| 日本女优一卡二卡在线观看-欧美大胆a级视频秒播| 小12萝自慰喷水亚洲网站-chinese偷拍一区二区三区| 成人免费黄色在线网站-日韩精品一区二区三区四区在线| 欧美视频在线观看国产专区-亚洲91精品在线观看| 91精品国产影片一区二区三区-欧美精品久久久精品一区二区| 日韩二级视频在线观看-美女扒开奶罩露出奶子的视频网站| 久久精品国产96精品-日韩人成理论午夜福利| 日本韩国亚洲欧美三级-日本东京不卡网一区二区三区| 亚洲精品激情一区二区-久久成人国产欧美精品一区二区| 亚洲精品一区网站在线观看-黄页视频免费观看网站| 国产一级片久久免费看同-麻豆精品尤物一区二区青青| 国产老熟女激情小视频-成人一区二区人妻不卡视频| 黄片黄片在线免费观看-激情综合网激情五月俺也去| 成人免费黄色在线网站-日韩精品一区二区三区四区在线| 欧美精品一区二区三区爽爽爽-日韩国产精品亚洲经典| 丝袜美腿人妻连续中出-在线观看日韩三级视频| 亚洲欧美精品在线一区-99热国产在线手机精品99| 亚洲愉拍自拍欧美精品app-亚洲一区不卡在线视频| 97人妻精品一区二区三区爱与-日韩精品亚洲专区在线观看| 欧美看片一区二区三区-人妻无卡精品视频在线| 中文字幕亚洲综合久久最新-久久精品视频免费久久久| 一区二区三区女同性恋-熟妇高潮一区二区高清网络视频| 国产欧美日韩中文字幕在线-国产伊人一区二区三区四区| 看肥婆女人黄色儿逼视频-秋霞电影一区二区三区四区| 一级小黄片在线免费看-亚洲欧美午夜情伊人888| 可以免费看污污视频的网站-日韩欧美不卡视频在线观看| 中文字幕精品一区二区日本99-青青国产成人久久91网|