您好, 歡迎來到化工儀器網(wǎng)! 登錄| 免費(fèi)注冊| 產(chǎn)品展廳| 收藏商鋪|
行業(yè)產(chǎn)品
當(dāng)前位置:上海信裕生物科技有限公司>>重組蛋白>>人重組蛋白>> MyoD抗原;成肌分化蛋白重組蛋白多種屬
上海信裕生物科技有限公司
生產(chǎn)商
上海市
50µg 1800元 99瓶可售
100µg 2880元 99瓶可售
更新時(shí)間:2024-11-25 18:44:14瀏覽次數(shù):1次
聯(lián)系我時(shí),請告知來自 化工儀器網(wǎng)CAS | 詳見說明書 | 純度 | > 95% |
---|---|---|---|
分子量 | 38.2kDa | 分子式 | 詳見說明書 |
供貨周期 | 一周 | 規(guī)格 | 50μg/100μg |
貨號(hào) | XY93329RPHu01 | 應(yīng)用領(lǐng)域 | 生物產(chǎn)業(yè) |
主要用途 | SDS-PAGE; WB |
Recombinant Myogenic Differentiation (MyoD)
成肌分化蛋白(MyoD)重組蛋白
[ PROPERTIES ]
Source: Prokaryotic expression
Host: E.coli
Residues: Met1~Leu320
Tags: N-terminal His Tag
Subcellular Location: Nucleus
Purity: > 95%
Traits: Freeze-dried powder
Buffer formulation: 20mM Tris, 150mM NaCl, pH8.0, containing 1mM EDTA, 1mM DTT,0.01% SKL, 5% Trehalose and Proclin300.
Original Concentration: 200µg/mL
Applications: Positive Control; Immunogen; SDS-PAGE; WB.
(May be suitable for use in other assays to be determined by the end user.)
Predicted isoelectric point: 5.6
Predicted Molecular Mass: 38.2kDa
Accurate Molecular Mass: 50kDa as determined by SDS-PAGE reducing conditions.
Phenomenon explanation:
The possible reasons that the actual band size differs from the predicted are as follows:
1.Splice variants: Alternative splicing may create different sized proteins from the same gene.
2. Relative charge: The composition of amino acids may affects the charge of the protein.
3. Post-translational modification: Phosphorylation, glycosylation, methylation etc.
4. Post-translation cleavage: Many proteins are synthesized as pro-proteins, and then cleaved to give the active form.
5. Polymerization of the target protein: Dimerization, multimerization etc.
[ USAGE ]
Reconstitute in 20mM Tris, 150mM NaCl (pH8.0) to a concentration of 0.1-1.0 mg/mL. Do not vortex.
[ STORAGE AND STABILITY ]
Storage: Avoid repeated freeze/thaw cycles.
Store at 2-8oC for one month.
Aliquot and store at -80oC for 12 months.
Stability Test: The thermal stability is described by the loss rate. The loss rate was determined by accelerated thermal degradation test, that is, incubate the protein at 37°C for 48h, and no obvious degradation and precipitation were observed. The loss rate is less than 5% within the expiration date under appropriate storage condition.
[SEQUENCE ]
[ IDENTIFICATION ]
[ IMPORTANT NOTE ]
The kit is designed for research use only, we will not be responsible for any issue if the kit was used in clinical diagnostic or any other procedures.
特別提示:本公司的所有產(chǎn)品僅可用于科研實(shí)驗(yàn),嚴(yán)禁用于臨床醫(yī)療及其他非科研用途!以實(shí)際收貨產(chǎn)品說明書為準(zhǔn),網(wǎng)站說明書僅供參考!
請輸入賬號(hào)
請輸入密碼
請輸驗(yàn)證碼
以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),化工儀器網(wǎng)對此不承擔(dān)任何保證責(zé)任。
溫馨提示:為規(guī)避購買風(fēng)險(xiǎn),建議您在購買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。