應(yīng)用領(lǐng)域 |
醫(yī)療衛(wèi)生,生物產(chǎn)業(yè),電子,航天,綜合 |
優(yōu)質(zhì)患者模擬器AECG100, 同步輸出 ECG 心電及 PPG 光學(xué)心率模擬訊號(hào),ECG 及 PPG 訊號(hào)間的 PWTT 脈搏波傳導(dǎo)時(shí)間可調(diào)整
符合國(guó)際最新醫(yī)療標(biāo)準(zhǔn):IEC 60601-2-47、YY 0885、YY 9706.247,適用于研發(fā)、法規(guī)符合性及產(chǎn)線測(cè)試
AECG100 ECG,PPG及PWTT多功能生理訊號(hào)測(cè)試儀
優(yōu)質(zhì)患者模擬器AECG100, 同步輸出 ECG 心電及 PPG 光學(xué)心率模擬訊號(hào),ECG 及 PPG 訊號(hào)間的 PWTT 脈搏波傳導(dǎo)時(shí)間可調(diào)整,符合國(guó)際最新醫(yī)療標(biāo)準(zhǔn):IEC 60601-2-47, China YY-0782,適用于研發(fā)、法規(guī)符合性及產(chǎn)線測(cè)試
產(chǎn)品詳情
產(chǎn)品簡(jiǎn)介
優(yōu)質(zhì)患者模擬器AECG100, 同步輸出 ECG 心電及 PPG 光學(xué)心率模擬訊號(hào),ECG 及 PPG 訊號(hào)間的 PWTT 脈搏波傳導(dǎo)時(shí)間可調(diào)整,符合國(guó)際新醫(yī)療標(biāo)準(zhǔn):IEC 60601-2-47, China YY-0782,適用于研發(fā)、法規(guī)符合性及產(chǎn)線測(cè)試
產(chǎn)品特點(diǎn)
多功能綜合性能測(cè)試儀,兼容于使用 ECG 心電及 PPG 光學(xué)心率技術(shù)穿戴式裝置
AECG100 ECG 模塊依據(jù)移動(dòng)式心電圖標(biāo)準(zhǔn)測(cè)試線路之要求設(shè)計(jì),輸出訊號(hào)符合醫(yī)療標(biāo)準(zhǔn),可選擇搭配單信道或雙信道光學(xué) PPG 模塊
AECG100 單信道光學(xué)模塊可提供 PPG 心率模擬訊號(hào),雙信道光學(xué)模塊提供 SpO2 血氧飽和度仿真訊號(hào)
PWTT 脈搏波傳導(dǎo)時(shí)間參數(shù)可調(diào)整,有效提升血壓測(cè)量算法準(zhǔn)確
不同測(cè)試項(xiàng)目的測(cè)試參數(shù)可儲(chǔ)存及讀取,可排序做整合測(cè)試,有效降低人為錯(cuò)誤,節(jié)省人力支出
可撥放原始資料 Raw Data 波形,重現(xiàn)臨床驗(yàn)證收集的資料
AECG 標(biāo)準(zhǔn)輔助軟件簡(jiǎn)化測(cè)試步驟,點(diǎn)擊鼠標(biāo)即可完成醫(yī)療標(biāo)準(zhǔn)所需測(cè)試
SDK 軟件開(kāi)發(fā)工具包提供用戶編寫(xiě)自動(dòng)化測(cè)試軟件的彈性
產(chǎn)品規(guī)格
ECG Mode Parameter | Specification |
---|
Main Output Voltage Resolution | 2.5μV (DAC resolution) |
Main Output Voltage Accuracy | ±1% for amplitudes of 0.5mVpp or higher |
Frequency/Pulse Repetition Rate Accuracy | ±1% |
Pacing Pulse Amplitude Range | ±1mV ~ ±1000mV |
Pacing Pulse Amplitude Accurcy | ±2mV pulse: ±1% >2mV pulse,<-2mV: ±10% |
Pacing Pulse Width Range | 0.1ms~2ms |
Pacing Pulse Width Resolution | 0.1ms |
Pacing Pulse Width Accuracy | ±5μs |
Pacing Pulse Rise/Fall Time | 5μs |
Pacing Pulse Overshoot | <1% |
Pacing Pulse Setting Time | <1% |
Sample Rate | 1K (Normal mode);10K (Raw data mode) |
Sample Rate Accuracy | Depend on system clock accuracy |
DC Offset Range (fixed, noise free, sourced from internal super capacitor) | -300mV, +300mV |
DC Offset Accuracy (fixed, noise free, sourced from internal super capacitor) | ±1% |
DC Offset Range (variable, may include up to 50μVpp noise) | 0~±500mV |
DC Offset Accuracy (variable, may include up to 50μVpp noise) | ±1% |
RCA Output Amplitude Range | ECG electrode output x1000, max 10V |
RCA Output Amplitude Accuracy | ±1% for amplitudes of 0.5Vpp or higher |
PPG Mode Parameter | Specification |
---|
BPM Range | 30~300BPM |
BPM Resolution | 1 BPM |
BPM Accuracy | ±1 BPM |
LED AC Level Reference Output Range (RCA) | 0~3 V(Full range) |
LED AC Level Reference Output Resolution | (1/3000) Full Range |
LED AC Level Reference Output Accuracy | ±6% |
Lumen Range | 50 ~ 925 Lux (full range) (5mm from diffusion film) |
Lumen Resolution | (1/3000) Full Range |
Lumen Accuracy | ±6% |
Light Wavelength Range | 525nm |
Light Wavelength Resolution | ±10nm |
S/N Ratio | >51dB (with USB isolator) |
PD Response Time (Rising) | 1μs Typical (Varies from DUT LED intensity) |
PD Response Time (Falling) | 1μs Typical (Varies from DUT LED intensity) |
PWTT Mode Parameter | Specification |
---|
Time Difference (PTTp, PTTf) Range | 0~1999ms (decrease with increased BPM) |
Time Difference (PTTp, PTTf) Resolution | 1ms |
Time Difference (PTTp, PTTf) Accuracy | ±1ms |
SpO2 Parameter | Specification |
---|
BPM Range | 30~300 BPM |
BPM Resolution | 1 BPM |
BPM Accuracy | ±1 BPM |
LED AC Level Reference Output Range (RCA) | 0~3V(Full range) |
LED AC Level Reference Output Resolution (RCA) | (1/3000 )full range |
LED AC Level Reference Output Accuracy (RCA) | ±6% |
PI (AC level/DC level) Range | 0.025% ~ 30% (AC/DC, varies with AC or DC level ) |
Light Wavelength Range | Red: 660nm; Infrared: 940nm or 880nm |
Light Wavelength Accuracy | Red:±10nm; Infrared: ±10nm |
S/N Ratio | >51DB (with USB isolator) |
PD Rising Response Time | 1μs Typical (Varies from DUT LED intensity) |
PD Falling Response Time Rising | 1μs Typical (Varies from DUT LED intensity) |
Spo2 (%) Range | 30%~99.99% |
Spo2 (%) Resolution | 1% |
Spo2 (%) Accuracy | Use first degree of polynomial to set R-curve, ±1~±3(%)@70~100(%)+specified accuracy of the DUT.Use second degree of polynomial to set R-curve,±1~±2(%)@70~100(%)+specified accuracy of the DUT
|