Current Calibrator to 20 A Exceptional Uncertainties
Voltage Calibrator to 1000 V Extremely User Friendly
Power Calibrator to 2400 W NIST Traceable

詳細(xì)介紹

 

Specifications

DC voltage

(1 digit in 2,000,000 resolution)
range % of value + % of range
0 µV - 20 mV 0.05 + 0.0 + 10 µV
20 mV - 200 mV 0.01 + 0.0 + 10 µV
200 mV - 2 V 0.003 + 0.0008
2 V - 20 V 0.003 + 0.0005
20 V - 240 V 0.003 + 0.0005
240 V - 1000 V 0.005 + 0.005


AC voltage

(1 digit in 2,000,000 resolution)
range % of value
+ % of range
% of value
+ % of range
% of value
+ % of range
  20 Hz - 10 kHz 10 kHz - 50 kHz 50 kHz - 100 kHz
1 mV - 20 mV 0.2 + 0.05 + 20 µV 0.20 + 0.10 + 20 µV 1.0 + 0.10 + 20 µV
20mV - 200mV 0.1 + 0.03 + 20 µV 0.15 + 0.05 + 20 µV 0.3 + 0.05 + 20 µV
200 mV - 2 V 0.025 + 0.005 0.05 + 0.01 0.2 + 0.05
2 V - 20 V 0.025 + 0.005 0.05 + 0.03 0.2 + 0.05
20 V - 240 V 0.025 + 0.010 - - - -
240 V - 1000 V 0.03 + 0.02 * - - - -

* valid for f < 1000 Hz

DC current

(1 digit in 2,000,000 resolution)
range % of value + % of range
1 µA - 200 µA 0.05 + 0.0 + 20 nA
200 µA - 2 mA 0.02 + 0.005
2 mA - 20 mA 0.01 + 0.003
20 mA - 200 mA 0.01 + 0.003
200 mA - 2 A 0.015 + 0.005
2 A - 20 A 0.02 + 0.010

AC current

(1 digit in 2,000,000 resolution)
range % of value
+ % of range
% of value
+ % of range
  20 Hz - 1 kHz 1 kHz - 5 kHz
1 µA - 200 µA 0.15 + 0.0 + 20 nA 0.30 + 0.10 + 20 nA
200 µA - 2 mA 0.07 + 0.01 0.20 + 0.05
2 mA - 20 mA 0.05 + 0.005 0.20 + 0.05
20 mA - 200 mA 0.05 + 0.005 0.20 + 0.05
200 mA - 2 A 0.05 + 0.005 - -
2 A - 20 A 0.10 + 0.03 - -

When option 130-50 Current coil is used, add accuracy 0.3 % of the set current to the value specified in the above table. Output current is multiplied by factor 50.

Resistance (4-wire)

(1 digit in 20,000 resolution)
range % of value
0 Ohm - 100 Ohm 0.03 + 10 mOhm
100 Ohm - 400 Ohm 0.015
400 Ohm - 2 kOhm 0.015
2 kOhm - 10 kOhm 0.015
10 kOhm - 40 kOhm 0.015
40 kOhm - 200 kOhm 0.015
200 kOhm - 1 MOhm 0.05
1 MOhm - 4 MOhm 0.1
4 MOhm - 20 MOhm 0.2
20 MOhm - 50 MOhm 0.5

Maximum allowed voltage on the load is 8 Vpk.

Capacitance (4-wire)

(1 digit in 20,000 resolution)
range % of value
900 pF - 2.5 nF 0.5 + 15 pF
2.5 nF - 10 nF 0.5 + 5 pF
10 nF - 50 nF 0.5
50 nF - 250 nF 0.5
250 nF - 1 µF 0.5
1 µF - 3.5 µF 1.0
3.5 µF - 5 µF 1.0
5 µF - 10 µF 1.5
10 µF - 50 µF 2.0

Maximum allowed voltage on the load is 8 Vpk.

Frequency

(1 digit in 2,000,000 resolution)
type PWM (pos, neg, sym) HF *
range 0.1 Hz - 100 kHz 0.1 Hz - 20 MHz
frequency unc. (%) 0.005 0.005
amplitude 1 mV - 10 V 2 V
amplitude unc. (%) 0.1 10
ratio 0.00 - 1.00 - -
ratio unc.(%) 0.05 - -

* Rise time < 5 ns

DC power, energy

(1 digit in 2,000,000 resolution)
quantity range % of value
+ % of range
voltage 200 mV - 240 V see voltage table
current 2 mA - 10 A 0.05 + 0.01

AC power, energy

(1 digit in 2,000,000 resolution)
quantity range accuracy
voltage 200 mV - 240 V see voltage table
current 2 mA - 10 A 0.05 % + 0.01 %
frequency 40 Hz - 400 Hz 0.005
power factor -1 - +1 0.005 - 0.0005
phase 0 - 360 ° 0.15 ° - 0.25 °

Setting time in energy mode 10 s - 1999 s.
Accyract of AC power depends on set value of voltage, current, phase. The best accuracy is 0.08 %. Accuracy in energy mode depends on set value of voltage, current, phase and time. The best accuracy is 0.09 %.

Resistance temperature sensor simulation

types Pt 1.385, Pt 1.392, Ni
range of R0 20 Ohm - 2 kOhm
range of temperature -200 °C - 850 °C
temperature accuracy 0.04 °C - 0.5 °C
temperature scale ITS 90, PTS 68

Thermocouple simulation

types R, S, B, J, T, E, K, N
range of temperature -250 °C - 1820 °C
temperature accuracy 0.4 °C - 4.0 °C
temperature scale ITS 90, PTS 68

Multimeter

quantity range accuracy
VDC (DC voltage) 0 - ± 12 V 0.01 % + 100 µV
mVDC (DC voltage) 0 - ± 2000 mV 0.01 % + 10 µV
mADC (DC current) 0 - ± 25 mA 0.02 % + 1 µA
FREQ (Frequency) 1 Hz - 15 kHz 0.005 %
R4W (Resistance) 0 - 2 kOhm 0.02 % + 100 mOhm
TRTD (RTD sensors) -150 - +600 °C 0.1 °C
TTC (TC sensors) -250 - +1820 °C 0.4 - 4 °C
SGS (strain gauge sensor) * depends on sensor 0.01 % + 10 µV + sensor unc.

* Supplying voltage 2 to 10 V DC, max. current 40 mA, input resistance > 100 MOhm
sensitivity 0.5 - 100 mV/V, displayed unit settable

Accessories included

Power line cable 1 pc  
Operation manual 1 pc  
Option 10/11 Test cable 2 pcs  
Option 40
 
Test cable for built-in multimeter, 2 banana terminals for DC voltage and current measurement.
1 pc

opt40

Option 60
 
Test cable for built-in multimeter, 4 banana terminals for resistance measurement as well as Pt/Ni sensor temperature measurement.
1 pc

opt60

Option 70
 
4-wire resistance adapter. The adapter provides a four wire return to the calibrator for making resistance measurements.
1 pc

opt70

Optional Accessories

Option 130-50 Current coil 50 turns. Suitable for clamp-on Current transformer testing.

130-50

Option 140-01 Cable adapter for multimeters.
 
The adapter provides support for the meter under test as well as a simple cable connection to the calibrator front panel terminals.

The Adapter is equipped with a built-in Pt-100 temperature sensor. The internal meter can measure ambient temperature and display it on the screen and automatically make cold junction compensation when the TC temperature sensor simulation is selected.

140-01

Option 140-41 Cable adapter for simultaneous applications.
 
Cable adapter is designed for low-voltage/current aplications to 20 VDC and 200 mADC. There are two fields on the adapter. The first contains terminals with the calibrator output signals, the second contains internal multimeter input terminals. Various calibration tasks can be fulfilled with the adapter, especially measurements where simultaneous generation of the calibrated signal and response of unit under test are required.

With the adapter, temperatures of external TC temperature sensors can be measured and displayed.
 
140-41
Option 140-02 Set of cables and adapters. It includes Option 140-01, Option 140-41, Option 10 2pcs, Option 11 2pcs, Option 20, Option 30, Option 40, Option 60, Option 70
Option 10 Test cable 20A/1000V (black)
Option 11 Test cable 20A/1000V (red)
Option 20 Test cable BNC/BNC 1m
Option 30 Test cable BNC/banana 1m
Cable GPIB IEEE-488, 2m
Cable RS-232 RS-232, 2m

Description
The Multifunction Calibrator Model 8080 functions as a Voltage Calibrator, Current Calibrator, Power Calibrator, Resistance Calibrator, Capacitance Calibrator and a Thermocouple Calibrator.  Having very low uncertainties, the Multifunction Calibrator is ideal as a standard of these electric quantities in calibration laboratories. The Multifunction Calibrator also has the feature of supplying several different waveshapes in additional to the traditional sinusoidal output.  This feature makes it ideal for testing meters which are true rms reading or crest factor sensitive.  These signals are also suitable for the basic calibration of oscilloscopes. The Multifunction Calibrator has the capability of measuring temperature with TC and RTD temperature sensors. A built-in multimeter can be used independently or in simultaneous operation with  the Multifunction Calibrator output.

Basic Functions
In the Voltage Calibrator mode, the Multifunction Calibrator generates  DC/AC voltages up to 1000 V and in the Current Calibrator mode it generates DC/AC currents up to 20 A . Using a 50-turn transformer, the AC current range can be extended to 500 A. The best accuracy of the calibrator on DC voltage ranges is 0.0035%, on AC voltage ranges 0.03%, on DC current ranges 0.013% and on AC current ranges 0.055%. The frequency range is from 20 Hz to 100 kHz. The calibrator can generate periodic non-harmonic signals with a defined crest factor. Such signals can be used to test the sensitivity of multimeters to distorted signals. The Multifunction Calibrator simulates both resistance and capacitance. The resistance  range extends to 50 MOhm and the capacitance range is from 1 nF to 50 µF.  The precision of both quantities is sufficient for the calibration of commonly used hand-held multimeters. The basic accuracy of the resistance ranges and capacitance ranges is 0.03%, and  0.5% respectively. The resistance calibration may be used with both DC and AC signals up to 1 kHz.

The frequency function of the calibrator makes it possible to generate a square wave signal with adjustable and calibrated duty cycle, frequency and amplitude in the range from 1 mV to 10 V in the frequency band up to 10 kHz. In the  HF mode a square wave signal up to 20 MHz with a very low risetime can be generated. The frequency function is suitable for the calibrations of corresponding frequency ranges of multimeters, and for calibration of the channel sensitivities and time bases of the oscilloscopes.

In the Power Calibration mode, the Model 8080 can be used as a source to calibrate  DC and single-phase AC watt meters, power analyzers, and energy meters. In this mode, the output voltage can be set up to 240 V, the output current up to 10A, and the the power factor in range from -1 to +1 in the frequency band from 20 Hz to 400 Hz. The current capability of the voltage output is 30 mA so that analog watt meters, which usually have lower input impedances at their voltage input, may be calibrated.. For calibration of thermometers and temperature regulators, the temperature function is simulated by the Multifunction Calibrator. It is able to simulate all commonly used Pt and Ni resistance sensors as well as TC sensors of the R, S, B, J, T, E, K and N types. Compensation of the TC cold junction is made either by entering a value from the keyboard, or automatically by measuring the ambient temperature with a Pt-100 sensor. The precision of the simulated resistance and TC sensors depends on set value and type of the sensor. For resistance sensors the accuracy band is in the range from 0.04 °C to 0.5 °C, for TC sensors from 0.4°C to 4.0 °C.

Built-in multimeter
An internal multimeter with basic ranges of 20 mA, 200 mV, 10 V and 2 kOhm is a standard feature off the Multifunction Calibrator. With an accuracy of 0.01%, it enables the user to measure the output signals of various types of transducers.  With external strain gauge sensors, pressure, torsion, strength, etc. can be measured and displayed.

Calibrator - Tester
The Multifunction Calibrator can be used both as a precision signal source for a device under test and as a meter to measure the resultant voltages generated by the device. Programmable capability of the calibrator enables the user to set 10 steps of a testing procedure.  The testing can run automatically, and after it is completed, PASS/FAIL status is displayed. With the testing function, isolated relay contacts activated by the FAIL indicator, make it possible to control other equipment.

User friendly
The Model 8080 Calibrator is equipped with a number of other functions which make it extremely easy to use. Among them, are the capability to set relative deviations from the actual value of the selected output signal, the continuous displaying of the output signal accuracy, and the internal calibration procedure. The large, easy to read, comprehensive luminescent display contains all of the necessary information to set up any of the Multifunction Calibrator's functions. In addition, frequently used functions have specific keys assigned to them. The calibrator is equipped with the IEEE-488.2 interface and with the RS-232 serial interface.

Operation
The operation of the Model 8080 display, front panel keyboard and front panel terminals can be seen iillustrated by clicking on the links below.

收藏該商鋪

請(qǐng) 登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
二維碼 意見(jiàn)反饋
在線留言
国产午夜精品理论片A级漫画-久久精品国产99亚洲精品| 久久精品亚洲无中文东京热-日本妹子内谢视频一区| 在线成色中文综合网站-国产二区精品视频在线观看| 成人免费黄色在线网站-日韩精品一区二区三区四区在线| 日本中文字幕啊啊啊啊-久久精品伊人久久精品伊人| 国产在线一区二区三区欧美-久久偷拍精品视频久久| 99热在线精品免费6-av一区二区在线观看| 午夜精品午夜福利在线-内射无套内射国产精品视频| 久久网址一区二区精品视频-日产国产欧美视频一区精品| 国产精品一区二区欧美视频-国产一区二区三区天码| 91麻豆免费在线视频-欧美中文天堂在线观看| 日韩精品一区二区三区粉嫩av-欧美亚洲国产中文字幕| 日韩综合精品一区二区-丝袜美腿熟女人妻经典三级| 小12萝自慰喷水亚洲网站-chinese偷拍一区二区三区| 日韩精品亚洲不卡一区二区-成人网在线视频精品一区二区三区| 国产剧情av中文字幕-五月婷婷在线手机视频| 久久亚州天堂一区二区-色噜噜色哟哟一区二区三区| 国产欧美日韩精品一区在线-久久精品视频免费获取地址| 麻豆久久国产精品亚洲-日本理论中文字幕在线视频| 久久网站中文字幕精品-三级精品久久中文字幕| 日韩欧美国产综合久久-国产精品一起草在线观看| 交换朋友的妻子中文字幕-日本美女8x8x8x8| av一区免费在线观看-中文字幕日韩国产精品视频| 国产欧美一区二区三区嗯嗯-欧美一区二区日本国产激情| 亚洲另类自拍唯美另类-99国产精品兔免久久| 亚洲国产日韩精品四区-dy888午夜福利精品国产97| 国产精品成人欧美激情-黄色床上完整版高清无遮挡| 中文字幕偷拍亚洲九色-亚洲视频不卡一区二区天堂| 婷婷综合在线视频观看-亚洲一区二区三区香蕉| 18禁真人在线无遮挡羞免费-中文字幕精品一区二区三区四区| 久久精品国产亚洲av湖南-竹菊精品一区二区三区| 国产美女裸露无遮挡双奶网站-国产精品色午夜视频免费看| 欧美字幕一区二区三区-好吊妞欧美一区二区在线观看| 国产一级片久久免费看同-麻豆精品尤物一区二区青青| 久久精品国产96精品-日韩人成理论午夜福利| 午夜福利院免费在线观看-久久精品日产第一区二区三区画质| 国内精产熟女自线一二三区-六月丁香婷婷在线观看| 日本中文字幕永久在线人妻蜜臀-欧美一区二区的网站在线观看| 成人免费黄色在线网站-日韩精品一区二区三区四区在线| 婷婷综合在线视频观看-亚洲一区二区三区香蕉| 日本亚洲精品中字幕日产2020-很黄很黄的裸交视频网站|