產(chǎn)品簡介

產(chǎn)地類別 進口
Sentinel 501 生產(chǎn)線安全測試儀進行AC和DC介電強度測試,高達500VA(100mA)的功率輸出。

詳細介紹

Seaward Sentinel Series Comparison
Features200500501
Earth/ground Bond  
AC dielectric strength - 5kV
DC dielectric strength - 6kV
DC insulation resistance  
200VA (40mA)  
500VA (100mA) 
ARC detection

Sentinel 500/Sentinel 501

AC Dielectric Strength

Programmable Voltage Range:0.100 kV - 5.000 kV (2V/Step Resolution)
Frequency Independent of Supply:50 or 60 Hz Selectable
Output Voltage Accuracy:±1% + 5 Volts (No Load)
Voltage Display Resolution:0.001kV
Current Measurement:0.001mA - 100.0mA
Range and Accuracy:±1.5% + 30 Counts when trip limit <1.11mA
±1.5% ± 3 Counts when trip limit >1.11mA
Current Display Resolution:0.001mA / 0.001mA / 0.1mA
Selectable Range of Pass/Fail Levels:0.001mA - 100.00mA
Maximum Rated Current:100mA (0.5kV ≤ V ≤ 5kV)
10mA (0.1kV ≤ V ≤ 0.5kV)
Arc Detection:Yes
Ramp time:0.1 - 999.9s
Test Time:Off / 0.5s - 999.9s

 

DC Dielectric Strength

Programmable Voltage Range:0.100 kV - 6.000 kV
(2V/Step Resolution)
Frequency Independent 50 or 60 Hz Selectable of Supply:50 or 60 Hz Selectable
Output Voltage Accuracy:±1% + 5 Volts (No Load)
Voltage Display Resolution:0.001kV
Current Measurement:0.001mA - 20.0mA
Range and Accuracy:±1.5% + 30 Counts when trip limit <1.11mA ±1.5% + 3 Counts when trip limit >1.11mA
Current Display Resolution:0.001mA / 0.001mA / 0.1mA
Selectable Range of Pass/Fail Levels:0.001mA - 20.00mA
Maximum Rated Current:20mA (0.5kV ≤ V ≤ 5kV)
2mA (0.1kV ≤ V ≤ 0.5kV)
Arc Detection:Yes
Ramp time:0.1 - 999.9s
Test Time:Off / 0.5s - 999.9s

 

Sentinel 501 Only

Earth Bond

Programmable Test Current:03.00A - 32.00A ac
Test Current Resolution:0.01A
Test Current Accuracy:3A - 8A: (1% of rdg+0.2A)
8A - 32A: (1% of rdg+0.05A)
Test Voltage:6V AC max (open circuit)
Test Voltage Frequency:50Hz/60Hz selectable
Resistance Measurement Range:10mΩ - 650.0mΩ
Resistance Measurement Resolution:0.1mΩ
Resistance Measurement Accuracy:(1% of rdg + 2mΩ)
Test Time:0.5 - 999.9s
Arc Detection:Yes

 

Insulation Resistance

Output Voltage:50V - 1000V
Output-Voltage Resolution:50V / Step
Output-Voltage Accuracy:±(1% of setting +5V)[no load]
Resistance Measurement Range:0.001GΩ -50.00GΩ
Test Voltage: 
50V - 450V0.001 - 0.050GΩ
0.001 - 0.500GΩ
500V - 1000V0.051 - 2.000GΩ
0.501 - 9.999GΩ
10.00 - 50.00GΩ
Selectable Range of Pass/Fail Levels:0.001mA - 20.00mA
Output Impedance:Yes
RAMP (Ramp-Up Time):600kΩ
TIMER (Test Time):1s~999.9s

 

Sentinel 200

AC Dielectric Strength

Programmable Voltage Range:0.100 kV - 5.000 kV (2V/Step Resolution)
Frequency Independent of Supply:50 or 60 Hz Selectable
Output Voltage Accuracy:±1% + 5 Volts (No Load)
Voltage Display Resolution:0.001kV
Current Measurement:0.001mA - 40.0mA
Range and Accuracy:±1.5% + 30 Counts when trip limit <1.00mA
±1.5% ± 30 Counts when trip limit ≥1.00mA
Current Display Resolution:0.001mA / 0.001mA / 0.1mA
Selectable Range of Pass/Fail Levels:0.001mA - 40.00mA
Maximum Rated Current:40mA (0.5kV ≤ V ≤ 5kV)
10mA (0.1kV ≤ V ≤ 0.5kV)
Arc Detection:Yes
Ramp time:0.1 - 999.9s
Test Time:Off / 0.5s - 999.9s

 

DC Dielectric Strength

Programmable Voltage Range:0.100 kV - 6.000 kV
(2V/Step Resolution)
Frequency Independent 50 or 60 Hz Selectable of Supply:50 or 60 Hz Selectable
Output Voltage Accuracy:±1% + 5 Volts (No Load)
Voltage Display Resolution:0.001kV
Current Measurement:0.001mA - 10.0mA
Range and Accuracy:±1.5% + 30 Counts when trip limit <1.11mA ±1.5% + 3 Counts when trip limit >1.11mA
Current Display Resolution:0.001mA / 0.001mA / 0.1mA
Selectable Range of Pass/Fail Levels:0.001mA - 20.00mA
Maximum Rated Current:10mA (0.5kV ≤ V ≤ 6kV)
2mA (0.1kV ≤ V ≤ 0.5kV)
Arc Detection:Yes
Ramp time:0.1 - 999.9s
Test Time:Off / 0.5s - 999.9s

 

 

General Specification

Case Dimensions and Weight

Sentinel 500330W x 140H x 482D mm
Approx 24kg
Sentinel 501330W x 148H x 587D mm
Approx 27kg
Sentinel 200330W x 150H x 460D mm
Approx 15kg

Part Number

Sentinel 500489A920
Sentinel 501489A921
Sentinel 200489A910

Services

1 year warranty subject to product registration with Seaward, visit www.seaward.co.uk/register-product
Service and calibration by Calibrationhouse

Standard Accessories

Instruction Manual
Test Lead Set (High Voltage Cables x 2)
Interlock Key
Remote Terminal Plug
Power Cord
Test Lead Set (Earth Bond Cables x 2) Sentinel 501 Only