詳細介紹
西門子伺服控制器S120啟動跳F07410報警維修,西門子數控系統(tǒng)報230021功率單元接地故障排查電機及動力電纜接地磨損問題,加工中心顯示驅動器過載報警230005伺服電機負載不重怎么報功率單元過載呢,驅動器誤測報警更換功率單元修復,S120啟動報F07802故障維修,S120變頻器報F31885處理,S120主軸驅動器報F07800維修,西門子828D報201481接口壞維修,201315驅動不可運行,201482故障,207800沒功率單元,25201軸Z1伺服故障,西門子S120報F30025和230005過載,西門子數控系統(tǒng)207900出現故障,西門子S120報警F07900,25201,21612,西門子S120驅動器F31885,數控系統(tǒng)231885電機報故障,西門子電機報F07412,電機報警F07900,828D報警207862總線外部故障,206200整流單元故障,F31111,F31115,F31125,F31116,F31135,207016,231129,231101,F07412,F07410,231885,25001,25201,230885,231885,840DSL報警號,軸Y1驅動器故障,軸Y1伺服故障,802D加工中心025202軸Y1短期內驅動故障,828D數控系統(tǒng)025201軸Y1伺服故障,828D報警231100編碼器零標記距離出錯,21612軸MSP1故障,MSP1伺服故障報警,231101編碼器零標記故障,25201軸MSP1伺服故障,6SL3120-1TE28-5AA3維修,故障修復包括:西門子S120報警380500代碼故障維修,西門子6SL3120伺服驅動器維修,西門子6SL3130電源維修,西門子6SL3121伺服模塊維修,西門子802D數控系統(tǒng)驅動器維修,西門子802DSL控制器模塊維修,接地故障維修,RDY燈閃爍維修,F30021故障維修,F23004故障維修,F07800報警故障維修,過流維修,欠壓維修,F30897故障維修,F30005故障維修,F07930代碼維修,F07801故障維修,25201故障維修,F30027故障維修,模塊短路維修,跳閘維修,燈不亮維修,輸出電壓低維修,風扇報警維修,溫度故障維修,電路板壞維修等等。6SL3310-1TE36-1AA0,報A30042故障,達到或超過風扇的使用壽命
西門子S120整流單元報警F6200代碼故障,S120整流單元一個或者多個主電源相位故障解決方法:
原因: 一個或幾個主電源相位的故障或過壓。
故障可能在兩種運行狀態(tài)下出現:
1. 在整流單元接通期間。
測量出的主電源角度偏離了 3 相位系統(tǒng)的常規(guī)曲線,無法進行 PLL 的同步。
如果在使用電壓監(jiān)控模塊 VSM 運行時,VSM 上的相位分配 L1、L2、L3 與功率單元上的相位分配不同,接通后會緊接著出現故障。
2. 在整流單元運行期間。
在發(fā)現一個或者幾個電相位上出現電壓暫降或過壓后 ( 注意 A06205),100 ms 之內出現故障 (如可能,參見其它的信息)。一般在故障信息 F06200 之前至少會出現一次報警 A06205,其報警值會提示主電源故障的原因。西門子伺服控制器S120啟動跳F07410報警維修