應用領域 | 醫(yī)療衛(wèi)生,生物產業(yè),電子,航天,綜合 |
---|
Compliant with IEC 60601-2-25, IEC 60601-2-27, IEC 60601-2-47, GB 9706.225, GB 9706.227, YY 9706.247, YY1079, YY1139, YY0782, YY0885, JJG 760, JJG 1042, ANSI/AAMI EC11, ANSI/AAMI EC13
Built-in test circuits as defined in ECG standards
Adjustable parameters and selectable options enable to verify DUT with flexibility
Provides NST noise simulation
Electrode Motion Artifact / Muscle Noise / Baseline WanderVarious signal simulations
Impedance Type Respiration, Wave Modulation Type (Baseline / Amplitude / Frequency) Respiration and lead-off simulationAuto Sequence function assists in conducting semi-automated tests
Loads and plays recorded or programmed waveforms
Software Development Kit (SDK) allows to develop customized or automated test software with less efforts
Optional Standard Assistant software pack simplifies the medical standard with test sequences, options, parameters and pass criteria
Simulates ECG and PPG signals to conduct SpO
and PWTT (Pulse Wave Transit Time) testingAdjustable SpO
parameters, such as AC, DC, and PI values of R/IR, to confirm the accuracy of DUTsBuilds or loads the R curve of the SpO
function to quickly verify products' performance and assist in comparing against competitorsBuilt-in 14 types of ambient light signals and respiratory variation simulation
add-on signals for more authentic testingSynchronizes ECG and PPG signals while enabling users to adjust the time difference to test the accuracy of non-invasive blood pressure measurement algorithms
Simulates ECG and PPG signals to conduct SpO
and PWTT (Pulse Wave Transit Time) testingAdjustable SpO
parameters, such as AC, DC, and PI values of R/IR, to confirm the accuracy of DUTsBuilds or loads the R curve of the SpO
function to quickly verify products' performance and assist in comparing against competitorsBuilt-in respiratory variation simulation
add-on signals for more authentic testingSynchronizes ECG and PPG signals while enabling users to adjust the time difference to test the accuracy of non-invasive blood pressure measurement algorithms
Outputs green light analog signals to simulate PPG signals
Built-in respiratory variation simulation
add-on signals for more authentic testingSynchronizes ECG and PPG signals while enabling users to adjust the time difference to test the accuracy of non-invasive blood pressure measurement algorithms
Equipped with RCA to BNC ports to connect to an oscilloscope
outputs amplified and stable signals for viewing the voltage of AC analog signals of green light, optical signals received by the PPG-1R-525, and the switch status of green LED of DUT請輸入賬號